380v GCS AC Indoor Low voltage Power Distribution Cabinet

380v GCS AC Indoor Low voltage Power Distribution Cabinet

    Packaging & Delivery

    Packaging DetailsWooden case

    Delivery TimeShipped in 15-40 days after payment


Share

    Executive Standard:

    Standard numberDescription
    GB7251Low voltage switchgear and controlgear
    IEC60439Low voltage switchgear and controlgear assemblies
    IEC60529Standards and degrees of protection by enclosures


    380v GCS AC Indoor Low voltage Power Distribution Cabinet

    Technical Parameter

    Operating Conditions:

    NO.DescriptionRequirement
    1Ambient temperature-5°C—+40°C
    2Daily average temperature(Within 24h) ≤35°C
    3Altitude(Indoor installation) ≤2000Meter
    4Relative humidity50%(+40°C)—90%(+20°C)
    5Inclination(Vertical installation) ≤5°

    Particular attention:

    *The product shall be installed in a place where there is no severe vibration and is not enough to cause the electrical components to be corroded.

    *When customers have special requirements, we can negotiate to provide special custom services.


    Technical Parameter:

    NO.DescriptionUnitData
    1Rated voltage of auxiliary circuitACV220/380/400
    DCV110/220
    2Rated frequencyHZ50/60
    3Rated insulation voltageV660/1000
    4Rated currentHorizontal busbarA≤4000
    Vertical busbar(MCC)A1000
    5Rated short-time withstand currentKA50/80
    6Rated peak withstand currentKA105/176
    7Power frequency test voltageMain circuitV1890
    Auxiliary circuitV1500
    8BusbarThree-phase four-wire system/A/B/C/NPE
    Three-phase five-wire system/A/B/C/N/NPE
    9Protection degree/IP30



Executive Standard:

Standard numberDescription
GB7251Low voltage switchgear and controlgear
IEC60439Low voltage switchgear and controlgear assemblies
IEC60529Standards and degrees of protection by enclosures


380v GCS AC Indoor Low voltage Power Distribution Cabinet

Technical Parameter

Operating Conditions:

NO.DescriptionRequirement
1Ambient temperature-5°C—+40°C
2Daily average temperature(Within 24h) ≤35°C
3Altitude(Indoor installation) ≤2000Meter
4Relative humidity50%(+40°C)—90%(+20°C)
5Inclination(Vertical installation) ≤5°

Particular attention:

*The product shall be installed in a place where there is no severe vibration and is not enough to cause the electrical components to be corroded.

*When customers have special requirements, we can negotiate to provide special custom services.


Technical Parameter:

NO.DescriptionUnitData
1Rated voltage of auxiliary circuitACV220/380/400
DCV110/220
2Rated frequencyHZ50/60
3Rated insulation voltageV660/1000
4Rated currentHorizontal busbarA≤4000
Vertical busbar(MCC)A1000
5Rated short-time withstand currentKA50/80
6Rated peak withstand currentKA105/176
7Power frequency test voltageMain circuitV1890
Auxiliary circuitV1500
8BusbarThree-phase four-wire system/A/B/C/NPE
Three-phase five-wire system/A/B/C/N/NPE
9Protection degree/IP30