    Production Instruction

    AGSN switchgear is 12kV air-insulated switchgear featuring modular design. The switchgear uses

    Schneider AS12 three-position SF6 switches which are assembled in complete set factory, characterized

    by simple structure, flexible scheme, easy-to-use, high safety and reliability. Based on different applications

    and various user demands, satisfactory solutions will be provided.


    Medium-voltage/low-voltage Substation

    Definitions

    The followings are ASGN Series products used for medium-voltage/lowvoltage

    substations and industrial and mining power distribution stations

    ISC: load switch incoming line, outgoing line or connecting cabinet

    QSC: fuse + load switch combination cabinet

    ESC: Disconnector + vacuum circuit breaker cabinet

    PSC: voltage transformer cabinet

    GC: current/voltage metering cabinet

    DSC: dual power supply incoming line cabinet

    GB: bus lifting cabinet

    GA: incoming cable connection cabinet

    CSC: Transformer Cabinet for Substation

    Other cabinets: please consult with the manufacturer


    Normal Application

    The medium-voltage electric energy generated by power plant is transmitted to high-voltage power grid through MV/HV main transformer.

    In general, the electric power is transmitted to primary substation through overhead line.

    In HV/MV primary substation, the electric power is converted into medium voltage from high voltage.

    in MV/MV primary substation, the electric power is transmitted to several secondary substations at lower level. The circuit breakerplays an important role in power transmission and distribution.


Production Instruction

AGSN switchgear is 12kV air-insulated switchgear featuring modular design. The switchgear uses

Schneider AS12 three-position SF6 switches which are assembled in complete set factory, characterized

by simple structure, flexible scheme, easy-to-use, high safety and reliability. Based on different applications

and various user demands, satisfactory solutions will be provided.


Medium-voltage/low-voltage Substation

Definitions

The followings are ASGN Series products used for medium-voltage/lowvoltage

substations and industrial and mining power distribution stations

ISC: load switch incoming line, outgoing line or connecting cabinet

QSC: fuse + load switch combination cabinet

ESC: Disconnector + vacuum circuit breaker cabinet

PSC: voltage transformer cabinet

GC: current/voltage metering cabinet

DSC: dual power supply incoming line cabinet

GB: bus lifting cabinet

GA: incoming cable connection cabinet

CSC: Transformer Cabinet for Substation

Other cabinets: please consult with the manufacturer


Normal Application

The medium-voltage electric energy generated by power plant is transmitted to high-voltage power grid through MV/HV main transformer.

In general, the electric power is transmitted to primary substation through overhead line.

In HV/MV primary substation, the electric power is converted into medium voltage from high voltage.

in MV/MV primary substation, the electric power is transmitted to several secondary substations at lower level. The circuit breakerplays an important role in power transmission and distribution.