    SVS outdoor low voltage reactive power automatic compensation box suitable for urban and rural power distribution transformer low voltage side, Function of distribution, control power, protection equipment and so on . At the same time can be monitored in real-time, display, record with operating data and realize remote data transmission, realize low voltage reactive power automatic compensation, can effectively improve the quality of power supply, to provide the power supply reliability, reduce reactive power loss, reduce power loss rate SVS outdoor low voltage reactive power automatic compensation box running data to achieve with GPRS real-time communication and can be linked to the original background system application

    0.4Kv Svs Outdoor Low Voltage Reactive Power Automatic Compensation Box

    Product Standards &Technical Requirement

    GB/T 15576-2008


    Working Conditions

    a.The ambient air humidity is not higher than +45℃ , and no less than -10℃ , and the daily average temperature is not higher than +35℃ .

    b.Outdoor installation, with the ability to work in All day outdoor environment

    c.The air relative humidity when it is+25℃ less than 95%, should be taken into account due to changes in the environment may occasionally produce moderate condensation.

    d.The surrounding medium is not explosive and flammable, and is not enough to damage the insulation and corrosion of metal gas,no electric dust

    e.Installation site without severe vibration and bumps, according to the inclination of not more than 5°

    f.The use of voltage fluctuation range is not more than the rated working voltage of ±10%, the limit voltage is not more than ±20% of the rated working voltage, when the use of conditions or other requirements, by negotiated with manufacturer and user.


Overview

SVS outdoor low voltage reactive power automatic compensation box suitable for urban and rural power distribution transformer low voltage side, Function of distribution, control power, protection equipment and so on . At the same time can be monitored in real-time, display, record with operating data and realize remote data transmission, realize low voltage reactive power automatic compensation, can effectively improve the quality of power supply, to provide the power supply reliability, reduce reactive power loss, reduce power loss rate SVS outdoor low voltage reactive power automatic compensation box running data to achieve with GPRS real-time communication and can be linked to the original background system application

0.4Kv Svs Outdoor Low Voltage Reactive Power Automatic Compensation Box

Product Standards &Technical Requirement

GB/T 15576-2008


Working Conditions

a.The ambient air humidity is not higher than +45℃ , and no less than -10℃ , and the daily average temperature is not higher than +35℃ .

b.Outdoor installation, with the ability to work in All day outdoor environment

c.The air relative humidity when it is+25℃ less than 95%, should be taken into account due to changes in the environment may occasionally produce moderate condensation.

d.The surrounding medium is not explosive and flammable, and is not enough to damage the insulation and corrosion of metal gas,no electric dust

e.Installation site without severe vibration and bumps, according to the inclination of not more than 5°

f.The use of voltage fluctuation range is not more than the rated working voltage of ±10%, the limit voltage is not more than ±20% of the rated working voltage, when the use of conditions or other requirements, by negotiated with manufacturer and user.